Fuller’s earth transformer oil regeneration plant CMM-R (capacity 200 – 6000 LPH)


mineral oil regeneration plant

GENERAL: oil-immersed apparatus treatment
 CMM-R Transformer Oil Regeneration Plants are designed to improve dielectric strength and chemical composition of insulating oils. It is important to maintain oil properties within the recommended standards to prevent weakening of cellulose insulation by products of oil degradation. Since the life of the transformer is determent by the state of cellulose insulation, intervention is necessary to prevent sludge from destructing chemical bonds which hold the cellulose together. Oil Regeneration allows to remove sludge (which is formed as a result of oil degradation (aging) and consists mainly of acids, aldehydes and peroxides),  improve acidity level and decrease oil’s ability to dissolve gases.

     Comparing to older technology where Fuller’s Earth is used only once and then must be disposed of together with oil and harmful contaminants, CMM-R plants utilize the principle of sorbent (Fullers Earth) reactivation and have a number of unique features:
- regenerate the oil on energized transformer;
- remove sludge from cellulose insulation;
- reactivate the sorbent (Fuller’s Earth) allowing the sorbent to stay in the plant for 2-3 years before replacement is needed;
- oil regeneration and Fuller’s Earth reactivation is fully automatic;
- disposal of sorbent is environmentally friendly and safe as Fuller’s Earth is free from oil and contaminants.

Technical specifications

Parameter

Value

1.     Max. oil flow speed through the plant, m3/h

6

2.     Duration of sorbent reactivation, h

16

3.     Max. power consumption, kW

45

4.     Sorbent total amount, kg

1500

5.     Oil amount using for sorbent reactivation, % from processed

0,5

6.     Theoretical ratio of amount of the processed oil to amount of the sorbent, kg/kg

1/4

7.     Theoretical amount of sorbent reactivations

300

8.     Dimensions, not more  mm

 

-         Length

5150

-         Width

2090

-         Height

2102



Main principle of Oil Regeneration is to draw oil through the sorbent (Fuller’s Earth). During this process oil undergoes “molecular filtration” in the microporous sorbent. By-products of oil ageing are removed and stay in the Fuller’s Earth granules.
After the sorbent has accumulated certain amount of contaminants, CMM-R plant switches into sorbent reactivationmode. This unique fixture allows to regenerate oil continuously and managed by software installed on the operator’s laptop or plant’s PLC.  Reactivation of the sorbent is fully automated and enables the plant to process oil using the same Fuller’s Earth up to 300 times which is equal to 2 or 3 years of operation before sorbent replacement is required. Fuller’s Earth is a clay occurring in nature and possess no environmental danger and can be disposed as a construction waste after it exhausted it sabsorbing properties.

bleaching clay

System’s efficiency and reliability allows to  treat any mineral transformer oil to comply with all relevant international standards (please see table below). CMM-R Plants provide better alternative to oil replacement as treated oil parameters in most cases surpass those offered by new oil. As a rule timely oil regeneration extends transformer’s life by 25 to 30 years.

 

Table below shows typical oil parameters before and after treatment.

Parameter

Test Methods

Before regeneration

After regeneration

Appearance

Visual

Cloudy brown

Clear and transparent

Acid number, mg КОН/g

IEC 296; ASTM D-664

0.63

0.01

Corroding sulfur

ISO 5662; ASTM D-1275

Gained  

None

Mass moisture content, ppm

IEC 733; ASTM D-1533

170

5

Breakdown voltage, kV

IEC 156; ASTM D-1816

11

73

Dielectric loss tangent for 90ºС

IEC 247; ASTM D-924

4.0

0.001

Bulk gas content, %

IEC 60599; ASTM D-3612

12

0.1

Surface stretching, Н/m, for 25ºС

ISO 6295; ASTM D-2285

22

45

Mechanical contaminants size, micron

 

50

5

Oxidizing steadiness:

Acid number, mg КОН/g

IEC 1125А; IEC 1125B; IP-307

---

0.2

 

PLANT APPLICATION

GlobeCore’s Oil Regeneration Plants are design to carry out regeneration on energized and de-energized transformers as well as on tank to tank basis. This system is ideal for waste oil disposal.

Regeneration of Oil in transformer

Oil shall be taken and tested at the beginning of oil regeneration inside a transformer. The results will show duration (number of passes) required to regenerate the oil. Dissolved gas results will indicate whether transformer may be treated in energized or de-energized state.

Usually Regeneration Plant is used on 50 % to 80% of its production capacity while treating energized transformers to ensure laminar movement inside of transformer oil tank. With average oil characteristics it takes 8 to 10 passes to regenerate oil to “like new” conditions.

While treating de-energized transformers the Plant can be used on 100% of its production capacity.

 Desludging

Desludging of transformers requires oil temperature to be above aniline point usually around 80 C. Constant circulation of oil shall be maintained during desludging and oil must be new or regenerated.

This process will be more efficient on energized transformer as winding vibration and generated heat will also help to remove sludge. With average oil parameters it takes 10-20 passes to desludge energized transformer and up to 50 passes on de-energized transformer.

 Tank to tank Regeneration

After a time period when oil is left in a storage tank to settle out suspended solids and free water regeneration is carried out on 20-25% of the Plant’s production capacity to regenerate the oil to “like new” conditions in 1 pass.

 Available Models

Model

Degassing Unit

Regeneration Unit

 

Model

 

Capacity

litres/hour

Model

Fuller’s earth amount, kg

СММ-2R/600

CMM-0,6

600

СММ-2R

300

СММ-6R/1000

CMM-1

1000

СММ-6R

800

СММ-6R/3000

CMM-3

3000

СММ-6R

800

СММ-12R/4000

CMM-4

4000

СММ-12R

1600

СММ-12R/6000

CMM-6

6000

СММ-12R

1600

СММ24R/10000

CMM-10

10000

СММ-24R

3600

CMM-R Plants can be supplied with different from above production capacities if required. CMM-R capacities are measured in liters per hour in Degassing and Filtration modes, and in liters drown through Fuller’s Earth in Regeneration mode. Capacity is calculated basing on initial oil acidity of 0,2mg KOH/g and is equal to 4 liters of regenerated oil per 1 kg of Fuller’s Earth. Amount of Fuller’s Earth required to treat oils with higher or lower acidity level will increase or decrease proportionally.

PLANT’S DESIGN AND OPERATION

CMM-R comprises degassing and regeneration units.

Plant’s design allows for stationary as well as mobile operation when mounted on roadworthy trailer.

CMM-R is fully controlled via SCADA system from a Laptop positioned within the Operators compartment and a touchscreen on the control panel. Unit has automated mode with Air Compressor automated control system as well as manual operational mode.

During operation degassing and regeneration units shall be connected to a transformer. Oil is drawn into degassing unit where it is heated to operational temperature and filtered. Oil is than pumped into regeneration unit and back to degasser for moisture and dissolved gasses removal.

Plant’s design includes Fuller’s Earth reactivation insitu for continuous reuse of Fuller’s Earth. Fuller’s Earth regeneration facility will allow oil processing to be carried out using 1 set of columns whilst the other set is reactivating. Alternatively oil processing or reactivation could be carried out in all columns.


CONNECTION DIAGRAM

restoration of transformer

SYSTEM OPTIONS

Transformer Level Monitor

The Plant itself does not change oil level in the transformer tank. But if oil level drop in the transformer tank occurs, due to damaged pipes or seals, Transformer Level Monitor will shut down automatic valve installed at the bottom of the transformer and prevent oil drainage from the transformer.

Generator

Power generator provides ability to operate the plant without external power source.

Cable Reel

Manual or motorized cable reel with 50 m of cable is provided for ease of cable handling.

Additive Injector (Inhibition Unit)

To inject additives (inhibitors) removed from oil during regeneration Additive Injector (Inhibition Unit) is provided.

Moisture Analyser

To continuously monitor moisture level in the treated Moisture Analyser is available with one or two probes for inlet only or for inlet and outlet. Analyser’s readings are displayed on operator’s laptop and on the control cabinet’s touchscreen. Alarms could be set for certain values to constantly monitor moisture level and alert operator if this values are higher than required.

Consumables

Set of coarce (5 micron) and fine (2 micron) filters is provided as standard and sufficient for 5 years of operation.
2 sets of spare parts (one for Regeneration Unit and another one for Degassing Unit) are supplied to ensure efficient and trouble free operation of the plant.













Call us to purchase equipment or to get free 20-minutes consulting.